NEC4 Option A CL46 queries
|
|
2
|
821
|
7 January 2022
|
NEC3 ECC: Can the Contractor approach the adjudicator to determine a termination dispute
|
|
1
|
565
|
26 March 2015
|
NEC3 PSC Compensation Events
|
|
1
|
1004
|
29 January 2019
|
A contract under JCT Standard Building Contract 2009 is split into sections. Dates for possession and completion have been included within each section. Section 2 cannot commence until the completion of section 1. Must possession of section 2 be given on
|
|
1
|
1004
|
6 February 2013
|
What precautions should be adopted when removing bird droppings from a construction site?
|
|
1
|
1004
|
25 January 2013
|
Which Party owns terminal float?
|
|
1
|
1004
|
15 November 2012
|
NEC ECS: Error in BOQ and MoM description
|
|
2
|
819
|
9 February 2019
|
NEC3 TSC - Compensation Events Assessment
|
|
1
|
564
|
31 December 2020
|
At whose risk are Claims, proceedings, compensation and costs payable which are due to negligence, breach of statutory duty or interference with any legal right by the Employer or by any person employed or contracted to him except the Contractor?
|
|
1
|
564
|
10 October 2012
|
NEC ECC: Amending a rate in BOQ due to inconsistency between BOQ and Works Information
|
|
3
|
709
|
1 July 2020
|
Accepted programme
|
|
3
|
708
|
25 June 2022
|
NEC3 ECSS - Insurance Table
|
|
0
|
1416
|
19 January 2021
|
NEC ECS: Option B - Does PWDD include value of unimplemented Compensation Events?
|
|
1
|
563
|
10 July 2019
|
NEC ECC: Can an accepted programme under NEC be retracted for a wrong contract Completion Date
|
|
1
|
1001
|
11 March 2020
|
NEC ECC & TSC: Terminology difference for Options A&C between ECC and TSC
|
|
1
|
1001
|
18 September 2019
|
Are there any legal consequences to carrying out electrical work when not registered as a competent person?
|
|
1
|
1000
|
15 February 2013
|
NEC3 ECC: Do you include a programme when you submit a compensation event under Option B?
|
|
1
|
562
|
6 March 2016
|
What should the Contractor do with the certificates he receives from the Contractor proving that the insurance required by the contract is in force?
|
|
1
|
562
|
11 October 2012
|
In the event of an employer buying materials which are stolen on site, who accepts liability?
|
|
1
|
999
|
4 February 2013
|
What does Inset Village / Village Envelope mean in a planning context?
|
|
1
|
998
|
28 January 2013
|
NEC ECC: Change to Programme due to Employer's Risk not occurring
|
|
2
|
458
|
12 March 2018
|
Should the NEC Supervisor / Project Manager confirm in writing that a Defect has been rectified
|
|
1
|
560
|
25 August 2016
|
NEC3 ECC: Is Damage to Existing Infrastructure a Disallowed Cost?
|
|
1
|
560
|
17 January 2016
|
NEC3 ECC: If the Contractor makes a successful claim against another company is the Employer entitled to this?
|
|
1
|
560
|
7 July 2015
|
NEC ECC: Removal of completion criteria for Key Date
|
|
1
|
559
|
4 April 2019
|
The Project Manager has become aware of a matter which could delay meeting a Key Date. What should he do?
|
|
1
|
559
|
12 October 2012
|
The Employer has terminated because the Contractor has passed a resolution for winding-up (R7). What is the amount due?
|
|
1
|
559
|
12 October 2012
|
How often should a scaffold be inspected?
|
|
1
|
994
|
25 January 2013
|
NEC ECS: Data for Shorter Schedule of Cost Components
|
|
1
|
993
|
19 February 2019
|
NEC ECC: Can the client limit payment to agreed target value only on option C.
|
|
5
|
573
|
19 March 2019
|
NEC ECSC - omission of works
|
|
2
|
810
|
5 July 2019
|
Does the Contractor have to submit an application for payment under NEC4 in order to be entitled to payment?
|
|
1
|
992
|
3 May 2017
|
Does a Compensation Event comprise an instruction to carry out additional works?
|
|
3
|
702
|
5 November 2023
|
PSC Contract Option A - Hourly Rates for Compensation Event
|
|
3
|
701
|
15 June 2022
|
NEC ECC: Who carries the risk when a subcontractor goes into administration
|
|
1
|
991
|
4 May 2020
|
The Contractor has terminated because the Employer has presented his petition for bankruptcy (R1). What is the termination procedure?
|
|
1
|
557
|
12 October 2012
|
At whose risk is loss of or wear to the parts of the works taken over by the Employer after issue of the Defects Certificate?
|
|
1
|
557
|
10 October 2012
|
How long does the Project Manager have to assess the compensation event after receiving the Contractor’s notification?
|
|
1
|
557
|
9 October 2012
|
How to assess a "delay" to a Key Date for an instruction to change a Key Date under NEC 4 Cl 14.3
|
|
1
|
99
|
29 January 2025
|
How is a compensation event assessed if the Contractor fails to give an early warning?
|
|
1
|
990
|
9 October 2012
|
NEC ECC: Are there any disadvantages from employer perspective of leaving tenderers to define activities?
|
|
1
|
989
|
3 March 2020
|
NEC3 Framework Contract
|
|
1
|
989
|
25 September 2016
|
NEC ECC: New ECI Clauses: How is change managed during Stage 1?
|
|
1
|
556
|
23 May 2017
|
Does a Party have to terminate when the other Party is faced with bankruptcy, receivership or administration?
|
|
1
|
556
|
12 October 2012
|
NEC ECC: Rock found during excavation works
|
|
2
|
807
|
17 October 2019
|
NEC ECS: Under NEC3 option A contract, can an appointed subcontractor use the money gained from selling unused scrap on other works in the project?
|
|
1
|
987
|
17 June 2020
|
NEC ECC: Is Radiodection Equipment classed as Survey Equipment?
|
|
1
|
555
|
25 May 2017
|
NEC3 ECC: Is a programme accepted by default?
|
|
1
|
555
|
22 April 2016
|
NEC ECC: CE Quotations - Prospective or Retrospective
|
|
1
|
986
|
23 May 2018
|
X5 &7- Contractor cost incurred
|
|
1
|
554
|
20 May 2016
|